2249 products/mounting types in database

Ceiling tile, fiberglass

Finishes with no thickness information available
Manufacturer Model Thickness Mount Type Density Details
AsonaCloud PanelE-200
  • tested product thickness unclear
AsonaCloud PanelA
  • tested product thickness unclear
AsonaMonopanelE-400
  • tested product thickness unclear
EurocousticAtrium(R) 40 mmE-200
EurocousticAtrium(R) or Atrium(R) Office 25 mmE-200
EurocousticAtrium(R) or Atrium(R) Office Silver 25 mmE-200
EurocousticAtrium(R) Silver 25 mmE-200
EurocousticEquation(R)E-200
EurocousticErmes(R)E-200
EurocousticSamoa(R) AE-200

15 mm thick
Manufacturer Model Thickness Mount Type Density Details
EcophonAdvantage A15 mm
  • 50 mm depth of construction
  • ISO Class C
EcophonAdvantage A15 mm
  • 90 mm depth of construction
  • ISO Class B
EcophonAdvantage A15 mm
  • 110 mm depth of construction
  • ISO Class A
EcophonAdvantage A15 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonAdvantage E15 mm
  • 60 mm depth of construction
  • ISO Class C
EcophonAdvantage E15 mm
  • 90 mm depth of construction
  • ISO Class B
EcophonAdvantage E15 mm
  • 110 mm depth of construction
  • ISO Class A
EcophonAdvantage E15 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonGedina A15 mm
  • 50 mm depth of construction
  • ISO Class C
EcophonGedina A15 mm
  • 80 mm depth of construction
  • ISO Class B
EcophonGedina A15 mm
  • 90 mm depth of construction
  • ISO Class A
EcophonGedina A15 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonGedina E15 mm
  • 60 mm depth of construction
  • ISO Class C
EcophonGedina E15 mm
  • 80 mm depth of construction
  • ISO Class B
EcophonGedina E15 mm
  • 110 mm depth of construction
  • ISO Class A
EcophonGedina E15 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonHygiene Meditec A15 mm
  • 50 mm depth of construction
  • ISO Class C
EcophonHygiene Meditec A15 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonHygiene Meditec E15 mm
  • 60 mm depth of construction
  • ISO Class C
EcophonHygiene Meditec E15 mm
  • 200 mm depth of construction
  • ISO Class A

5/8 inch thick
Manufacturer Model Thickness Mount Type Density Details
ArmstrongPebble5/8 inchE-400
  • Open Plan CAC Backing
  • 24 inch x 48 inch x 5/8 inch
ArmstrongRandom Fissured Perforated #29105/8 inchE-400
  • 24 inch x 48 inch x 5/8 inch
ArmstrongShasta Unperforated #29075/8 inchE-400
  • 24 inch x 48 inch x 5/8 inch
ArmstrongTierra #34605/8 inchE-400
  • 24 inch x 24 inch x 5/8 inch
  • CAC not applicable
Owens CorningRandom Fissured5/8 inchE-405
  • film faced
Owens CorningShasta5/8 inchE-405
  • film faced

3/4 inch thick
Manufacturer Model Thickness Mount Type Density Details
3/4 inchE-400
  • fiberglass tile
ArmstrongOptima Open Plan #39013/4 inchE-400
  • 24 inch x 24 inch x 3/4 inch
ArmstrongPainted Nubby3/4 inchE-400
  • Vector CAC Backing
  • 24 inch x 48 inch x 3/4 inch
ArmstrongPainted Nubby Open Plan #31013/4 inchE-400
  • 24 inch x 48 inch x 3/4 inch
  • CAC not applicable
Owens CorningNubby3/4 inchE-405
  • glass cloth faced
Owens CorningOmega3/4 inchE-405
  • glass cloth faced
Owens CorningRandom Fissured3/4 inchE-405
  • film faced
Owens CorningShasta3/4 inchE-405
  • film faced

20 mm thick
Manufacturer Model Thickness Mount Type Density Details
EcophonAccess C20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonAccess E20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus A20 mm
  • 50 mm depth of construction
  • ISO Class C
EcophonFocus A 20 mm
  • 80 mm depth of construction
  • ISO Class A
EcophonFocus A 20 mm
  • 100 mm depth of construction
  • ISO Class A
EcophonFocus A20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus B and C20 mm
  • 23 mm depth of construction
  • ISO Class C
EcophonFocus C20 mm
  • 35 mm depth of construction
  • ISO Class C
EcophonFocus C20 mm
  • 50 mm depth of construction
  • ISO Class B
EcophonFocus C20 mm
  • 75 mm depth of construction
  • ISO Class A
EcophonFocus C20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus D20 mm
  • 60 mm depth of construction
  • ISO Class B
EcophonFocus D20 mm
  • 75 mm depth of construction
  • ISO Class A
EcophonFocus D20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus DG20 mm
  • 65 mm depth of construction
  • ISO Class B
EcophonFocus DG20 mm
  • 75 mm depth of construction
  • ISO Class A
EcophonFocus DG20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus Ds20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus E20 mm
  • 60 mm depth of construction
  • ISO Class B
EcophonFocus E20 mm
  • 80 mm depth of construction
  • ISO Class A
EcophonFocus E20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus Ebx20 mm
  • 110 mm depth of construction
  • ISO Class A
EcophonFocus Ebx20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus F20 mm
  • 20 mm depth of construction
  • ISO Class C
EcophonFocus F20 mm
  • 40 mm depth of construction
  • ISO Class C
  • on secondary spaced boarding
EcophonFocus F20 mm
  • 428 mm depth of construction
  • ISO Class A
  • on secondary spaced boarding backed with mineral wool
EcophonHygiene Advance A20 mm
  • 200 mm depth of construction
  • ISO Class B
EcophonHygiene Foodtec A20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonHygiene Labotec Ds20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonHygiene Performance A20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonHygiene Protec A20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonSombra A20 mm
  • 50 mm depth of construction
  • ISO Class C
EcophonSombra A20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonSombra A/gamma20 mm
  • 50 mm depth of construction
  • ISO Class E
EcophonSombra A/gamma20 mm
  • 200 mm depth of construction
  • ISO Class D
EcophonSombra D20 mm
  • 50 mm depth of construction
  • ISO Class B
EcophonSombra D20 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonSombra D/gamma 20 mm
  • 50 mm depth of construction
  • ISO Class E
EcophonSombra D/gamma 20 mm
  • 200 mm depth of construction
  • ISO Class E
EcophonSuper G20 mm
  • 22 mm depth of construction
  • ISO Class D
  • impact resistant
EcophonSuper G20 mm
  • 200 mm depth of construction
  • ISO Class A
  • impact resistant
EcophonSuper G Dp XL20 mm
  • 50 mm depth of construction
  • ISO Class C
  • impact resistant
EcophonSuper G Dp XL20 mm
  • 200 mm depth of construction
  • ISO Class A
  • impact resistant
PrimacousticStratoTile20 mm
  • 200 mm airspace
  • incomplete test report

7/8 inch thick
Manufacturer Model Thickness Mount Type Density Details
ArmstrongOptima7/8 inchE-400
  • Open Plan CAC Backing
  • 24 inch x 24 inch x 7/8 inch
ArmstrongOptima7/8 inchE-400
  • Vector
  • 24 inch x 24 inch x 7/8 inch
  • CAC-26
ArmstrongOptima Vector #39007/8 inchE-400
  • 24 inch x 24 inch x 7/8 inch
ArmstrongOptima Vector #39017/8 inchE-400
  • 24 inch x 24 inch x 7/8 inch

1 inch thick
Manufacturer Model Thickness Mount Type Density Details
1 inchE-400
  • film-faced fiberglass
1 inchE-400
  • fiberglass tile
ArmstrongOptima1 inchE-400
  • Open Plan
  • 24 inch x 24 inch x 1 inch
ArmstrongOptima1 inchE-400
  • Open Plan
  • 24 inch x 48 inch x 1 inch
  • CAC-27
ArmstrongOptima Open Plan #32511 inchE-400
  • 24 inch x 24 inch x 1 inch
ArmstrongOptima Open Plan #33551 inchE-400
  • 24 inch x 24 inch x 1 inch
  • foil-backed
  • CAC-20
ArmstrongPainted Nubby1 inchE-400
  • Open Plan
  • 24 inch x 48 inch x 1 inch
ArmstrongPainted Nubby1 inchE-400
  • Open Plan
  • 24 inch x 24 inch x 1 inch
  • CAC-24
ArmstrongPebble1 inchE-400
  • 24 inch x 48 inch x 1 inch
Owens CorningNubby1 inchE-405
  • glass cloth faced
Owens CorningOmega1 inchE-405
  • glass cloth faced
Owens CorningRandom Fissured1 inchE-405
  • film faced
Owens CorningShasta1 inchE-405
  • film faced
Owens CorningStonebrooke1 inchE-405
  • film faced

25 mm thick
Manufacturer Model Thickness Mount Type Density Details
AsonaAvant 25 Theatre Black25 mmE-200
AsonaTriton 2525 mmE-200
AsonaTriton Hygiene25 mmE-200
EcophonAccess A25 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonFocus DG25 mm
  • 65 mm depth of construction
  • ISO Class A
  • 1.2 m x 1.2 m
EcophonFocus DG25 mm
  • 200 mm depth of construction
  • ISO Class B
  • 1.2 m x 1.2 m

30 mm thick
Manufacturer Model Thickness Mount Type Density Details
EcophonCombison Uno D30 mm
  • 200 mm depth of construction
  • ISO Class C
  • gypsum board layer
EcophonIndustry Modus S30 mm
  • 30 mm depth of construction
  • ISO Class C
  • black
  • industrial
EcophonIndustry RTP30 mm
  • 30 mm depth of construction
  • ISO Class C
  • 3 mm perforations and 15% open area metal face
EcophonIndustry RTP30 mm
  • 200 mm depth of construction
  • ISO Class A
  • 4 mm perforations and 15% open area metal face

35 mm thick
Manufacturer Model Thickness Mount Type Density Details
AsonaTriton Duo 3535 mm
  • CAC-44
EcophonCombison Uno A35 mm
  • 200 mm depth of construction
  • ISO Class C
  • gypsum board layer
EcophonSuper G35 mm
  • 50 mm depth of construction
  • ISO Class A
  • impact resistant
EcophonSuper G35 mm
  • 200 mm depth of construction
  • ISO Class A
  • impact resistant

1-1/2 inch thick
Manufacturer Model Thickness Mount Type Density Details
1-1/2 inchE-400
  • fiberglass tile
ArmstrongOptima1-1/2 inchE-400
  • Open Plan CAC Backing
  • 24 inch x 48 inch x 1-1/2 inch
  • CAC-27
ArmstrongOptima Open Plan #32541-1/2 inchE-400
  • 24 inch x 24 inch x 1-1/2 inch
ArmstrongOptima Open Plan #33561-1/2 inchE-400
  • 24 inch x 48 inch x 1-1/2 inch
  • foil-backed
  • CAC-26
Owens CorningNubby1-1/2 inchE-405
  • glass cloth faced
Owens CorningOmega1-1/2 inchE-405
  • glass cloth faced

40 mm thick
Manufacturer Model Thickness Mount Type Density Details
AsonaTriton 40 Sport40 mmE-200
AsonaTriton 40 Sport40 mmA
EcophonHygiene Advance A40 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonHygiene Advance Baffle40 mm
  • 600 mm depth of construction
  • ISO Class D
  • oriented in rows c 600 mm
EcophonHygiene Advance Baffle40 mm
  • 600 mm depth of construction
  • ISO Class C
  • oriented in rectangles
EcophonHygiene Advance Wall40 mm
  • 80 mm depth of construction
  • ISO Class B
EcophonHygiene Foodtec A40 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonHygiene Foodtec Wall40 mm
  • 80 mm depth of construction
  • ISO Class A
EcophonHygiene Performance A40 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonIndustry Ambit 40 mm
  • 40 mm depth of construction
  • ISO Class A
EcophonIndustry Ambit40 mm
  • 60 mm depth of construction
  • ISO Class A
  • on secondary spaced boarding
EcophonMaster A/alpha40 mm
  • 50 mm depth of construction
  • ISO Class A
EcophonMaster A/alpha40 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonMaster A/beta40 mm
  • 50 mm depth of construction
  • ISO Class C
EcophonMaster A/beta40 mm
  • 200 mm depth of construction
  • ISO Class C
EcophonMaster A/gamma40 mm
  • 50 mm depth of construction
  • ISO Class E
EcophonMaster A/gamma40 mm
  • 200 mm depth of construction
  • ISO Class E
EcophonMaster B/alpha40 mm
  • 40 mm depth of construction
  • ISO Class A
EcophonMaster B/beta40 mm
  • 40 mm depth of construction
  • ISO Class C
EcophonMaster B/gamma40 mm
  • 40 mm depth of construction
  • ISO Class E
EcophonMaster Baffle40 mm
  • 200 mm depth of construction
  • ISO Class D
  • row 300 height 200
EcophonMaster Baffle40 mm
  • 300 mm depth of construction
  • ISO Class D
  • row 300 height 300
EcophonMaster Baffle40 mm
  • 300 mm depth of construction
  • ISO Class D
  • row 500 height 300
EcophonMaster C/alpha40 mm
  • 40 mm depth of construction
  • ISO Class A
EcophonMaster C/alpha40 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonMaster C/beta40 mm
  • 40 mm depth of construction
  • ISO Class C
EcophonMaster C/beta40 mm
  • 200 mm depth of construction
  • ISO Class C
EcophonMaster C/gamma40 mm
  • 40 mm depth of construction
  • ISO Class E
EcophonMaster C/gamma40 mm
  • 200 mm depth of construction
  • ISO Class E
EcophonMaster D/alpha40 mm
  • 95 mm depth of construction
  • ISO Class A
EcophonMaster D/alpha40 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonMaster D/beta40 mm
  • 105 mm depth of construction
  • ISO Class C
EcophonMaster D/beta40 mm
  • 200 mm depth of construction
  • ISO Class C
EcophonMaster D/gamma40 mm
  • 95 mm depth of construction
  • ISO Class E
EcophonMaster D/gamma40 mm
  • 200 mm depth of construction
  • ISO Class E
EcophonMaster E/alpha40 mm
  • 60 mm depth of construction
  • ISO Class A
EcophonMaster E/alpha40 mm
  • 200 mm depth of construction
  • ISO Class A
EcophonMaster E/beta40 mm
  • 60 mm depth of construction
  • ISO Class C
EcophonMaster E/beta40 mm
  • 200 mm depth of construction
  • ISO Class C
EcophonMaster E/gamma40 mm
  • 60 mm depth of construction
  • ISO Class D
EcophonMaster E/gamma40 mm
  • 200 mm depth of construction
  • ISO Class E
EcophonMaster F/alpha40 mm
  • 40 mm depth of construction
  • ISO Class A
EcophonMaster F/alpha40 mm
  • 60 mm depth of construction
  • ISO Class A
EcophonMaster F/beta40 mm
  • 40 mm depth of construction
  • ISO Class C
EcophonMaster F/gamma40 mm
  • 40 mm depth of construction
  • ISO Class E
EcophonMaster Solo S40 mm
  • 200 mm depth of construction
  • normalized to sample area 2 x 1.
  • 1200 mm x 1200 mm
EcophonMaster Solo S40 mm
  • 400 mm depth of construction
  • normalized to sample area 2 x 1.
  • 1200 mm x 1200 mm
EcophonMaster Solo S40 mm
  • 1000 mm depth of construction
  • normalized to sample area 2 x 1.
  • 1200 mm x 1200 mm
EcophonMaster Solo S40 mm
  • 200 mm depth of construction
  • normalized to sample area 2 x 1.
  • 1200 mm x 2400 mm
EcophonMaster Solo S40 mm
  • 400 mm depth of construction
  • normalized to sample area 2 x 1.
  • 1200 mm x 2400 mm
EcophonMaster Solo S40 mm
  • 1000 mm depth of construction
  • normalized to sample area 2 x 1.
  • 1200 mm x 2400 mm
EcophonSuper G Plus40 mm
  • 40 mm depth of construction
  • ISO Class A
  • impact resistant
EcophonSuper G Plus40 mm
  • 200 mm depth of construction
  • ISO Class A
  • impact resistant

50 mm thick
Manufacturer Model Thickness Mount Type Density Details
AsonaCloud Pool Panel50 mmE-200
AsonaCloud Pool Panel50 mmA
AsonaDefender 5050 mmA
AsonaDefender 5050 mmE-200
AsonaTriton 5050 mmE-200
AsonaTriton 5050 mmA
AsonaTriton 50 Bass50 mmE-200
AsonaTriton 50 Bass50 mmA
EcophonHygiene Foodtec Baffle50 mm
  • 600 mm depth of construction
  • ISO Class C
  • oriented in rows c 600 mm
EcophonHygiene Foodtec Baffle50 mm
  • 600 mm depth of construction
  • ISO Class C
  • oriented in rectangles
EcophonIndustry Al50 mm
  • 50 mm depth of construction
  • ISO Class A
  • perforated aluminum foil face
EcophonIndustry Modus S50 mm
  • 50 mm depth of construction
  • ISO Class A
  • nature, white and black, T, white
  • industrial
EcophonIndustry Modus S50 mm
  • 200 mm depth of construction
  • ISO Class A
  • nature, white and black, T, white
  • industrial
EcophonIndustry RTP50 mm
  • 50 mm depth of construction
  • ISO Class A
  • 5 mm perforations and 15% open area metal face
EcophonIndustry RTP50 mm
  • 200 mm depth of construction
  • ISO Class A
  • 6 mm perforations and 15% open area metal face

2 inch thick
Manufacturer Model Thickness Mount Type Density Details
2 inchE-400
  • film-faced fiberglass
Owens CorningStonebrooke2 inchE-405
  • film faced

54 mm thick
Manufacturer Model Thickness Mount Type Density Details
EcophonCombison Duo A54 mm
  • 200 mm depth of construction
  • ISO Class A
  • gypsum board layer
EcophonCombison Duo E54 mm
  • 200 mm depth of construction
  • ISO Class A
  • gypsum board layer

60 mm thick
Manufacturer Model Thickness Mount Type Density Details
AsonaTriton Duo 6060 mmE-200
  • CAC-44

75 mm thick
Manufacturer Model Thickness Mount Type Density Details
AsonaTriton 7575 mmE-200
AsonaTriton 7575 mmA

3 inch thick
Manufacturer Model Thickness Mount Type Density Details
3 inchE-400
  • film-faced fiberglass
Owens CorningStonebrooke3 inchE-405
  • film faced

80 mm thick
Manufacturer Model Thickness Mount Type Density Details
EcophonIndustry Al80 mm
  • 80 mm depth of construction
  • ISO Class A
  • perforated aluminum foil face

100 mm thick
Manufacturer Model Thickness Mount Type Density Details
AsonaTriton 100100 mmE-200
AsonaTriton 100100 mmA
EcophonIndustry Al100 mm
  • 100 mm depth of construction
  • ISO Class A
  • perforated aluminum foil face
EcophonIndustry Modus S100 mm
  • 100 mm depth of construction
  • ISO Class A
  • nature and white
  • industrial
EcophonIndustry Modus S100 mm
  • 200 mm depth of construction
  • ISO Class A
  • nature and white
  • industrial

120 mm thick
Manufacturer Model Thickness Mount Type Density Details
EcophonSombra A/gamma and Sombra X-Bass120 mm
  • 200 mm depth of construction
  • ISO Class E
EcophonSombra D/gamma and Sombra X-Bass120 mm
  • 200 mm depth of construction
  • ISO Class E

140 mm thick
Manufacturer Model Thickness Mount Type Density Details
EcophonMaster A/alpha + Master Extra Bass140 mm
  • 200 mm depth of construction
  • ISO Class A